šŸŽ‰ Up to 70% Off Selected ItemsShop Sale
HomeStore

Standard Red Screw-On Wire Connectors 22-10 AWG 400/Jar #WCS-Red-CD

Product image 1

Standard Red Screw-On Wire Connectors 22-10 AWG 400/Jar #WCS-Red-CD

Standard Red Screw-On Wire Connectors 22-8 400/Jar

Qty. 100

Twist-On

22-8 AWG

Min. 3 #18

Max. 2 #10 Sol Ā w/2 #12 Str

UL Recognized (US): Yes

CSA: Yes

WARNING: Shut off power before working on a circuit. Only use approved materials and adhere to all electrical codes

Do not use in wet or damp conditions.

FOR USE WITH COPPER TO COPPER
Temperature Rating: 105°C (221°F) Max.
Voltage Rating: 300V Max

Installation Instructions:
1. Turn off power before installing or removing connectors.
2. Strip wires 7/16" (11.1 mm). For #16 and smaller wires, strip 1/2" (12.7 mm).
3. Hold stripped wires together with ends even (lead stranded wires slightly). Pre-twisting is unnecessary.
4. Straighten frayed strands. Hold conductors parallel to each other.Ā 
5. Push wires firmly into connector. Screw on until two twists are visible in wires.
To be sold only with installation instructions

Shortened List of Wire Combinations:

2 #10 Sol
2 to 4 #12
2 to 6 #14
3 to 9 #18
1 #10 w/1 to 3 #12 or #14
1 #12 w/1 to 5 #14
4 to 6 #16
1 #12 w/2 #14 w/3 #16
1 #12 w/1 to 4 #20
3 #12 w/1 #14

$23.95
Standard Red Screw-On Wire Connectors 22-10 AWG 400/Jar #WCS-Red-CD—
$23.95

Product Information

Shipping & Returns

Description

Standard Red Screw-On Wire Connectors 22-8 400/Jar

Qty. 100

Twist-On

22-8 AWG

Min. 3 #18

Max. 2 #10 Sol Ā w/2 #12 Str

UL Recognized (US): Yes

CSA: Yes

WARNING: Shut off power before working on a circuit. Only use approved materials and adhere to all electrical codes

Do not use in wet or damp conditions.

FOR USE WITH COPPER TO COPPER
Temperature Rating: 105°C (221°F) Max.
Voltage Rating: 300V Max

Installation Instructions:
1. Turn off power before installing or removing connectors.
2. Strip wires 7/16" (11.1 mm). For #16 and smaller wires, strip 1/2" (12.7 mm).
3. Hold stripped wires together with ends even (lead stranded wires slightly). Pre-twisting is unnecessary.
4. Straighten frayed strands. Hold conductors parallel to each other.Ā 
5. Push wires firmly into connector. Screw on until two twists are visible in wires.
To be sold only with installation instructions

Shortened List of Wire Combinations:

2 #10 Sol
2 to 4 #12
2 to 6 #14
3 to 9 #18
1 #10 w/1 to 3 #12 or #14
1 #12 w/1 to 5 #14
4 to 6 #16
1 #12 w/2 #14 w/3 #16
1 #12 w/1 to 4 #20
3 #12 w/1 #14